Pollutant dispersion over Industrial Sub-urban area (Helwan)

Authors

  • M.A.El- Shahawi
  • A.B. MAYHOUB
  • S. M. ETMAN

DOI:

https://doi.org/10.54302/mausam.v43i3.3461

Keywords:

Gaussian plume model, Dispersion parameters, Air pollution, Stack height, Wind roses, stability parameters

Abstract

The concentration of pollutants released from one chimney of the National Company for cement production in Helwan industrial area has been calculated; The calculations are based on the Gaussian plume model covering the period June 1988-May .1989. A method has been presented to calculate the dispersion parameters ay and az in horizontal and vertical directions respectively. The method rely on two-level observation of both wind velocity and temperature. The plume rise correction recommended by Briggs has been adopted to calculate the effective release height (stack height~ plus the plume rise).. The maximum concentration values for different heights and their1otations have been calculated.

Downloads

Published

01-07-1992

How to Cite

[1]
M.-. Shahawi, A. . MAYHOUB, and S. M. ETMAN, “Pollutant dispersion over Industrial Sub-urban area (Helwan)”, MAUSAM, vol. 43, no. 3, pp. 311–314, Jul. 1992.

Issue

Section

Shorter Contribution